Always use whole field correction

If you know a certain field type is likely to have characters misread, you can configure Correction to put these fields into whole field correction mode from the beginning. This enables a user to type the entire contents of the field at once rather than each individual character using the single character correction mode. You can ensure that a field is always in whole field correction mode by following these steps:

  1. Open the Project Tree window if it is not already open.
  2. Expand the Project Tree and select the class that contains either an Advanced Zone Locator or anOCR Voting Evaluator.
  3. Optionally, view the class contents if they are not already displayed.

    The hidden class contents are displayed.

  4. Open the Details window if it is not already open.
  5. Expand the Fields collection Project Tree - Fields icon and select a field that requires correction.

    The Field Properties for the selected field is displayed in the Details window.

  6. In the User Interactive Modules group, select Display field for correction.

    The Field is displayed in whole field correction mode is enabled.

  7. In the "Field is displayed in whole field correction mode" list, select Always.

    The selected field always is displayed in whole field correction mode during Correction.

  8. Save the changes to your project.