Configure the verification settings for a folder type field

Configure fields inside a Folder (except tables) to allow for verification before releasing the fields to a back office system. You can select the verification mode and allow a reviewer to edit the field.

Exporting or importing a process that has a variable or a classification group referring to a folder includes verification settings configured for fields.

  1. Select a field for a field group in a folder and configure the settings in the Verification group.
  2. To display the field on the form at design time and runtime, click Yes for Display Field for Verification. (Default: No)
    Note The Table type does not support verification.
  3. Select one of the following verification modes:
    • Confirm: In this mode, if the data compared with the image is correct, the user presses a key to accept the data. Once you select this option, set the User may change Field Value option to allow or restrict editing a field after the field is accepted (confirmed). (Default: Yes; the user can edit the field)
    • Blind Double Keying: In this mode, the field is displayed with no value and the user must enter a value using the image as a reference. This value is compared with the original value from the last module that ran before verification. If the values do not match, a message appears. Once you select this option, set the Show Field Values if No Match option to allow a double-keyed field display values if there is a mismatch. (Default: No; field values are not displayed.)

      Note Only use Blind Double Keying for advanced users who will use this information as a guideline and who understand the importance of keying from the image rather than matching the original value.

    • Read-Only: In this mode, the field is set to read-only. You cannot edit the field.