General Tab

Use this tab to specify the general connection parameters.

Option Description
Activate Activate the component according to a condition. This option is only present in the eConnector component.

For more information about conditions, see Conditional Activation.

Server Specify the name of the server where the document will be uploaded.

Server address should be entered without protocol prefix and without domain name of the server; for example,

  • MyD3Server
  • 192.168.1.108

It is mandatory to fill out this text box.

Port Enter the port number, through which the component connects to the server. The default port number is 3400.
User Enter the name of the d.3 user account.
You should specify the value representing the "Username" property of the d.3 user account in this text box.
Obtain password via RRT Select this check box if you want to use an RRT to specify the password.
Password Enter the password for the user account, specified in the User field.

This text box is only enabled when the Obtain password via RRT check box is not selected.

Password RRT Enter an expression consisting of RRTs that will be replaced by the actual password at run time.

This text box is only enabled when the Obtain password via RRT check box is selected.

This field supports and returns values for encrypted by restricted RRTs. For more information, see Encrypted Field RRTs.

Archive Enter a database ID.
If the d.3 client is installed on the host machine, then the browse button (...) is enabled. Click the browse button and select an archive from the drop-down list in the open Select Archive dialog box.
Language Specify the connection language. There are two languages available: English and German. The English is the default language.
Pass through Set this option to Yes to pass the original document to subsequent components in the workflow. If this option is set to No, the component won't pass the input documents to the subsequent components in the chain. You can use conditions in this combo box. This option is available only in the eConnector configuration.

For more information about conditions, see Conditional Activation.

If you enter an invalid condition into Pass through box, the activation is Yes by default.